U value 0.31W/m2K

The Porotherm clay block system is a monolithic wall structure, so no cavity just solid wall. You will use these blocks for your external wall where is the thermal performance is important. Used from DPC (damp-proof course) up to roof plate level and also for gables. Available block sizes (wall thickness): 240mm, 300mm, 365mm, 425mm, 490mm. All block sizes available with or without integrated mineral wool insulation.

Category:

Description

External wall for bungalow or 2 storey house. It will need minimum 60mm external insulation to achive the current building regulation (U-value 0.21W/m2K) 100mm external insulation will provide U-value of 0.17W/m2K

Product Description Porotherm 300 T10 MW
Dimension in mm (LxWxH)
248 x 300 x 249
Quantity/sqm
16
Quantity/pack
60
Weight kg/each
12.1
Weight kg/pack
726
Conductivity Dry Block Lambda [W/mK]
0.10
Compressive strength
8

U-Value DAB and SLAB Finish

Heat Loss Value

Note: If you need to do your own calculation, you can find the Lambda value, for all the invidual blocks in the Products tab.

The numbers based on a 1mm parge coat, dab and slab finish internally, 15mm render externally.

Product Insulation Type and Thickness Provided U Value
Porotherm 300 T10 0.29W/m²K
Porotherm 300 T10 50mm EPS 0.20W/m²K
Porotherm 300 T10 100mm EPS 0.16W/m²K
Porotherm 300 T10 150mm EPS 0.13W/m²K
Porotherm 300 T10 200mm EPS 0.11W/m²K

U-Value Wet Plaster Finish

Heat Loss Value

Note: If you need to do your own calculation, you can find the Lambda value, for all the invidual blocks in the Products tab.

The numbers based on a 1mm parge coat, dab and slab finish internally, 15mm render externally.

Product Insulation Type and Thickness Provided U Value
Porotherm 300 T10 0.31W/m²K
Porotherm 300 T10 50mm EPS 0.22W/m²K
Porotherm 300 T10 100mm EPS 0.17W/m²K
Porotherm 300 T10 150mm EPS 0.13W/m²K